Recorded from the 21 November 2026 discussion.
Status: planning only. This document records the user’s decisions and the implementation ideas discussed around them. Swordfish does not yet implement this extension API, Cloud tab, account wizard, casting extension or email extension. No manifest format or message schema has been finalized.
portable-data.The proposed model is an out-of-process extension program. Swordfish starts it and exchanges versioned JSON messages over stdin/stdout; JSON-RPC was suggested as a possible protocol. This keeps the interface language-neutral and avoids loading extension code as a shared library inside the FOX process. Failure and timeout handling would still need designing; process separation alone does not provide a permission sandbox.
Possible API contributions discussed:
| Contribution | Examples |
|---|---|
| File and background context-menu actions, filtered for the selection | Cast selected files; cloud actions |
| Sidebar tabs and places with changing status | Cloud accounts; pinned mounted accounts |
| Toolbar buttons and dropdowns | Account selection |
| Status, notifications and progress | Mounting, uploads, casting |
| Settings pages | Initially a simple manifest-driven form |
| Send-to destinations | Email selected files |
| Calls into Swordfish | Read the selection; open a path or tab; refresh a folder |
Swordfish should draw contributed sidebar rows and forms using its own theme
rather than embedding an unrelated interface. A manifest would describe the
extension’s identity, version, supported platforms, API compatibility,
launcher, contributions, declared permissions and system prerequisites.
extension.ini was an example name, not an agreed file format.
The host would discover folders, check compatibility, ask before enabling a new extension, start/stop its process and handle messages. Permission declarations must not be presented as enforced restrictions unless an actual enforcement mechanism exists. An initial fake extension could exercise a left-pane tab, changing status and opening a folder before real cloud work. Custom Actions might later become a simple extension type; no migration or replacement of the existing feature was agreed.
An illustrative layout:
extensions/
cloud/
extension.ini
cloud-extension
bin/
rclone
providers/
providers.ini
icons/
data/
rclone.conf
cache/
logs/
licenses/
The proposed portable location is portable-data/extensions/cloud/. The
installed-build search location still needs defining.
An earlier suggestion put accounts/cache/logs in a separate
extension-data/cloud/ directory. The final single-folder decision
supersedes that suggestion. All extension-owned persistent data must remain
under the extension’s parent folder. Internal saved paths should be relative
and resolved against its current location.
Proposed lifecycle safeguards:
data/ directory was suggested, but its API contract is not finalized.
Blindly replacing the whole folder would lose accounts and is not an
acceptable update procedure.The future Swordfish build targets are amd64, i386, armhf and arm64; see the portable build documentation. Adding those targets to scripts is not proof that every extension or architecture has been tested.
The extension should use its own bundled rclone and its own nested config, not silently adopt a system rclone or modify the user’s unrelated rclone configuration. Importing existing remotes could be an explicit optional step.
The suggested backend is one rclone remote-control process (rclone rcd)
instead of starting a new command for every action. Listing remotes,
mount/unmount actions, supported quota information and transfer statistics
would flow through it. Its local endpoint, authentication and lifecycle need
specifying before implementation.
Mounted accounts appear as local folders, allowing existing file panels, tabs, bookmarks and transfers to work without a new virtual-filesystem layer. A full remote filesystem API would require a larger refactor and was deferred.
The proposed separate left-pane tab would offer:
The user requested a familiar, preconfigured list of popular providers because login methods, required credentials and two-factor authentication differ. The list should supply names, icons, backend identifiers, preset options, friendly labels, help links and sensible mount defaults. It must not duplicate or hard-code rclone’s changing authentication state machine.
Login categories discussed, with illustrative provider examples:
| Category | Proposed user flow |
|---|---|
| Browser/OAuth, such as Drive, OneDrive or Dropbox | Open the provider’s sign-in page; the provider handles password and 2FA |
| Interactive password/code flows | Prompt through the backend’s actual setup steps, including 2FA when required |
| App passwords, such as some WebDAV services | Explain where to create the provider’s app password |
| Access keys, such as S3-compatible services or B2 | Ask for the backend’s required keys, region and endpoint |
| Server login, such as SFTP | Ask for host and the supported password/key authentication |
These are planning categories, not verified promises of backend support or login behavior. Verify them against the rclone version bundled in the extension. The suggested starting list was Google Drive, OneDrive, Dropbox, Box, pCloud, MEGA, Proton Drive, Nextcloud/WebDAV, Backblaze B2, Amazon S3, Wasabi and SFTP. Other examples discussed included iCloud Drive, ownCloud, Koofr, Cloudflare R2, IDrive e2, Yandex, Zoho, SMB and FTP.
An Other provider option would expose additional backends with less curated guidance. rclone’s provider metadata and non-interactive configuration continuation were suggested for generating questions, filling preset answers, hiding optional advanced fields and handling provider-specific steps. Exact commands, flags and supported flows must be checked before coding.
Proposed add-account sequence:
Reconnect should reuse the account rather than delete it when authorization expires. Optional custom OAuth client IDs were discussed as an advanced setting, not a first-version requirement.
Credential storage is unresolved. A system keyring was initially suggested, but it does not travel with a copied extension. The later discussion included an encrypted rclone config with a session unlock and a portable master-password prompt; any unencrypted-storage choice would require explicit explanation and consent. rclone password obscuring must not be described as encryption. No passwords or tokens should be logged or stored in Swordfish’s general settings file. Secret storage and migration need a reviewed design.
Full sync remains out of scope, but normal writable mounts can still queue uploads. A file-manager copy finishing is not proof that the remote upload has finished. Show pending uploads and warn before unmount/exit when they remain.
Network-expensive thumbnails, previews and recursive folder sizing were suggested as off by default on cloud mounts, with per-account opt-in. Cache size limits and an explicit Clear cache action were also discussed. Never clear or omit pending-write data as if it were disposable cache. Automatic cache omission while copying a folder was an idea, not an approved exception to the requirement that copying an extension carries its data. Detect stale mounts after crashes; recovery must not discard queued uploads.
The original candidate list was multi-account cloud integration, a multi-account email client and casting to a TV.
Casting was initially suggested as the easiest proof of concept. The later discussion prioritized cloud and suggested a small fake cloud-facing test extension instead: casting alone would not test cloud tabs, mounts or account status. Casting remains a possible second extension, not a committed schedule.
Casting ideas included DLNA, Chromecast and AirPlay targets, a Cast-to submenu, a temporary local media HTTP server and a separate play/pause/seek/stop/queue window. Existing UPnP discovery could inform the implementation, but there is no implemented extension discovery API and no verified compatibility promise for those protocols.
For email, a full multi-account client was recognized as a much larger separate application. A narrower Send to email/account action for selected attachments, an optional recent-attachments place and an extension-owned compose window were proposed instead. The user has not finalized that scope.
Before implementation, review the extension API and manifest, installed and portable discovery paths, process lifecycle, Cloud tab contributions, credential protection, update/data preservation, mountpoint placement and copy/export behavior for mounted remotes, and mount/upload shutdown behavior. Confirm provider coverage against a pinned rclone version. The discussion authorized recording and refining the design, not implementing a broad plugin framework or shipping the proposed extensions.